Back to top

Managing Condensate Storage & Overflow

When it comes to commercial power generation, cogeneration (combined heat and power) or operating packaged boilers for process steam production, the recovery and storage of condensate plays an important role in overall operational cost and efficiency.

In addition to its energy content, condensate has real value in that every gallon recovered spares the cost of additional makeup water, makeup water treatment and discharge to municipal or other systems. Depending on your plant configuration the condenser hotwell, main condensate storage and/or overflow tanks provide the means to manage condensate inventory and, subsequently, make-up water requirements.

Magnetrol® has produced an applications brochure for the power and utilities industries, detailing measurement challenges and solutions for each step of the steam generation and condensate recovery processes. This blog post is part of an occasional series exploring each application in detail.

Condensate and make-up water storage tanks

Level Measurement Challenges and Consideration

Reliable and accurate point/continuous level technologies are critical in these applications to ensure sufficient supply of treated water is available to meet steam production demands as well as protect expensive hardware. Waste heat recovery through the use of flash steam also presents challenges related to level control. Oftentimes, it is the instrumentation, or lack thereof, that limits the performance of the overall system, causing the condensate and waste heat recovery processes to fall short of financial expectations.

Level Measurement Solutions

MAGNETROL has produced several level measurement solutions for condensate storage tanks:

  • For point level

Models B10 or B15 displacer-actuated switches

  • For continuous level

Eclipse® Model 706 guided wave radar transmitter; Pulsar® R96 pulse burst radar transmitter; Echotel® Model 355 non-contact ultrasonic level transmitter

  • For visual indication

Atlas™ or Aurora® magnetic level indicators

More Information

For more information on level solutions for condensate storage tanks or other commercial power generation, cogeneration and boiler applications, download the power industry brochure. You can also download oursteam generation white paperto learn more about solutions for the steam generation and condensate recovery cycle.